Labeled Doors
Single Doors :
| Door Series |
Max.Size |
Label Available |
| DS 416 |
4'0"x10'0" |
A,B,C,20 min |
| DP 416 |
4'0"x 8'0" |
B,C,20 min |
| DP 418 |
3'10"x 8'0" |
B,C,20 min |
1-3/8" doors can be labeled up to 45 minutes to a maximum size of 3'0" x 7'2".
The door must be 16 gauge steel stiffened.
Pairs of Doors :
| Door Series |
Max.Size |
Label Available |
| DS 416 |
4'0"x10'0" |
A,B,C,20 min |
| DP 416 |
4'0"x 8'0" |
B,C,20 min |
| DP 418 |
3'10"x 8'0" |
B,C,20 min |
| DH 418 |
4'0"x8'0" |
A,B,C,20 min |
Doors with Louvers :
| Door Series |
Max.Size |
Label Available |
| DS 416 |
4'0"x 8'0" |
B,C,20 min |
Fusible link louver required
Maximum Louver size: 24"x 24"
Glass lights for Fire Exit Hardware is not approved
Double Egress Doors and Frames :
| Door Series |
Max.Size |
Label Available |
| DS 416 |
8'0"x 8'0" |
B,C,20 min |
Frame Gauge: 16 and 14
Jamb Depth: 5" minimum to 14" maximum.
Vertical Rod Exit Devices required on each leaf.
Welded-on astragal required.
100 square inches of expoed glass permitted per leaf.
Stainless Doors :
| Door Series |
Max.Size |
Label Available |
| DH 416 |
3'4"x 8'0" |
A,B,C,20 min |
| DH 416 |
6'8"x 8'0" |
A,B,C,20 min |
| DH 416 |
7'0"x 7'2" |
B,C,20 min |
|
|